A modified Draize method was used as described in OECD Guidelines for the testing of Chemicals Sec. 404. Complies with the requirements of OECD Principles of GLP, Annex (rev. July 1992). Primary irritation score of .4 ± .01. Conclusion: NON-SKIN IRRITANT
Non-DOT Regulated/Non-DOT hazardous
Exempt as per 49CFR 173.154(d)(1)
DOT Classifies a material to be corrosive and hazardous if it has a corrosion rate that exceeds 6.25 mmpy on SAE C1020 carbon steel or 7075- Y6 Aluminum.
Results: SAE 1020 carbon steel – 0.00 mmpy
7075-Y6 aluminum – 0.00 mmpy
Conclusion: NON-CORROSIVE
When tested, SynClean HD showed no potential for the generation of carbon dioxide under NIOSH 7903 OSHA and ACGIH testing protocols.
Toxicity Limits: Test procedure OECD 202, 48 hours
LC 50 and LD 50 (rat oral): NON-TOXIC
Mutagenicity Limits: OECD Guidelines Sec. 471 Chemicals: NON-MUTAGENIC
Product is sold as concentrate. Always dilute with water.
Recommended dilution examples (Water/SynClean HD):
Hydraulic fluid – 5/1
Kitchen range hoods – 10/1
Vehicles – 30/1
Carpets – 30/1
Windows – 100/1
Apply. Wait momentarily. Brush or rinse with clean water. Repeat as desired.
Test Procedure: Hach Reactor Digestion method for waste water and sea water. Hach Reactor Digestion Method is a semi-micro adaptation of the Standard Methods.
SynClean HD is 100% BIODEGRADABLE
COD – low detectable limits
BOD – no detectable limits
DOT, TDG, IMO, IATA, IMDG, SARA 313, 311/312, and California Prop 65: Non-regulated
FDA: Approved as safe (GRAS)
USDA Authorization: A1, A2, A3, A4, A7, A8, C2